Improving Energy Efficiency in Data Centers and IT Rooms

23May/112

Data Centers, IT Rooms and Telecommunication Rooms are built most of the time without any consideration of energy efficiency. Data provided by IT department is exorbitantly high. Consequently CRAC’s selected for cooling duty are over designed. Placement of these cooling equipments is badly planned. Resultantly, despite availability of cooling capacity, indoor conditions are not satisfactory.
After couple of months in to operation, management decides to put additional cooling equipment to bring indoor conditions to desirable levels but without any improvement. It is observed that they consume two to three times required energy but to no advantage.
New Data Centers can be planned with latest technologies, reducing energy consumption. There are certain myths associated with new designs. Raised floor is considered to be indispensible for these areas. This is wrong. Most energy efficient data centers these days are built with solid floor. Indoor conditions are stated to be 19ºc. Today Rack equipment manufacturers allow temperatures from 22ºc to 27ºc. Humidity conditions also are not as stringent as previously considered. Either manufacturers have improved their equipment or previous information was overstated.
With existing set ups we can do lot of things to improve energy consumption. First and foremost is the analysis of hot spots or pockets. Most of the time air distribution through perforated tiles of raised floor is not proper. This results in to hot zones. Some areas are overcooled and others receive hot air. There is cross flow of air from hot to cold side. Thermo graphic techniques are utilized to analyze inside conditions. Racks of equal density are zoned together. If high density racks are placed close to low density, environmental conditions are difficult to control. Preferably these need to be grouped together according to their ratings.
Step two is aisle containment solution. No matter what type of system data room is cooled with, aisle containment is most economical and workable energy improvement strategy. It can be used both for hot aisle and cold aisle. Instead of going for replacements or additional CRAC’s, this route is less cumbersome and cost effective.
Step three is to avoid simultaneous processes of energy wastage. When distribution is not proper, reheat and useless humidification processes are done simultaneously. This wastes energy.
Chilled water based CRAH systems, close coupled systems and economizer operations are other energy conserving techniques.

Tagged as: Data Center Air Conditioning, eisting centers, energy efficiency
Leave a comment

Comments (2)
Trackbacks (0)
( subscribe to comments on this post )

  1. How can this be that you have such a lot brilliant issue about this topic? Just the professional dissertations writers know the right way to accomplish such great thesis writing service and buy dissertation.

    ( REPLY )
  2. Freelance writing work
    August 14th, 2011 – 03:38

    As you are really interested in some information just about this good topic, you have to run here writing job onlne service and I can tell you, you can get all the benefit!

    ( REPLY )

Leave a comment Cancel reply

(required)

(required)



No trackbacks yet.

Absorption Chiller Suppliers »
« Electric Chiller Suppliers

Recent Posts

  • OPTIMUM CHILLER PLANT SEQUENCE OF OPERATION
  • EFFICIENCY IMPROVEMENT AND OPERATING COST REDUCTION BY BUILDING BMS SYSTEM
  • Salient Features of Energy Efficient Homes
  • Interesting story idea for your readers
  • Coordinated Practices for Green Building Design
  • Use of Thermal Images for Indoor Environmental Control
  • Absorption Chiller Suppliers
  • Improving Efficiency of Existing Data Centers
  • Electric Chiller Suppliers
  • HVAC ENGINEER
  • HVAC ENGINEER
  • ENERGY EFFICIENT OPERATION OF COOLING TOWERS
  • Salient Features of Healthcare AHU
  • Multipurpose Hall Environment Control
  • Piping Network Considerations for Air Conditioning System

Categories

  • Absorption Chiller Suppliers
  • AHU Coils
  • Air Conditioning Systems
  • Air Distribution
  • Air Filtration
  • Air Handling Units
  • Building Management System
  • Chilled Water Plant ΔT
  • Chiller Plant Control Sequence
  • Chillers
  • Combined Cooling Heating & Power Systems
  • Cooling Towers
  • Cost Effective and Energy Efficient Air Side Economizer Systems
  • Data Center Air Conditioning
  • Demand Control Ventilation
  • Displacement Ventilation Systems
  • Ducting System
  • ELECTRIC CHILLER SUPPLIERS
  • Energy Efficient Pumping
  • Energy Recoveries
  • Fans For High Performing HVAC
  • Green Building Design
  • Green Solution
  • Hospital HVAC
  • How to Control Low Chilled Water delta-T
  • HVAC ENGINEERS
  • Indoor Air Quality
  • Insulations
  • Kitchen Ventilation
  • Night Time Precooling
  • Noise Control
  • Optimized Chiller Operation
  • Pumping Solutions
  • Refrigerant Pipng
  • Smoke Management Systems
  • Solar Energy Systems
  • Thermal Energy Storage for Cooling
  • Variable Frequency Drives
  • Variable-Flow Pumping Systems

Archives

 

April 2012
M T W T F S S
« Dec    
  1
2 3 4 5 6 7 8
9 10 11 12 13 14 15
16 17 18 19 20 21 22
23 24 25 26 27 28 29
30  

Recent Comments

  • HAVC Units on How to Achieve Low Humidity Conditions with Minimum Energy Consumption
  • dentist on Identifying Objectionable Noise Sources in Air Conditioning Systems
  • ideas for window treatments for bay windows on High Performance Strategies for Solar Protection
  • Bidet toilet seat on Best Location to Introduce Makeup Air in Commercial Kitchen
  • face exercises on Using Fiberglass Duct liner for Air Conditioning System Noise Mitigation

Meta

  • Log in
  • Entries RSS
  • Comments RSS
  • WordPress.org