Using Fiberglass Duct Liner to Reduce Air Conditioning Noise

1Dec/106

 In order to control noise levels originating from air conditioning apparatus sound liners are used. They are fitted inside ducts. Liner comes in air flow path. Sound liner material is fiberglass. Continuous air flow may damage liner facing. It is mixed with incoming air and spread in the conditioned space. When inhaled this material may cause allergies and other health related problems. Moist fiberglass liner is a breeding ground for growth of microorganisms. Their concentration in air circulation areas increases which degrades indoor air quality.

Fiberglass material may be lined with metallic or plastic sheets. It reduces bad effects of fiberglass spread. But effectiveness of the liner reduces with use of solid facing. Perforated facings are effective in this case, but it can trap moisture too. Fiberglass lining may be avoided by sizing duct at reduced velocity. Discharge velocity from unit exit can be reduced by use of plenums. This will increase duct area. Increased areas result in to low noise. Low velocity air travels in the main ducts. Main ducts are oversized. These occupy more space in ceiling void. But increasing size of the duct solves noise issues without use of fiberglass material.

Some tough materials are also available as duct liners. These don’t mix with air and provide smooth surfaces. Moisture carryover is reduced by using eliminators. With less moisture in the air, fiberglass when installed has long life. Fiberglass liners are also treated with special materials which retard microbial growth. This is also helpful in long life of fiberglass material.

Tagged as: Air Conditioning, Duct Liner, Fiberglass, HVAC, Indoor Air Quality, Sound Attenuation
Leave a comment

Comments (6)
Trackbacks (0)
( subscribe to comments on this post )

  1. Sometimes I question the internet and what is posted? Honestly the internet used to be like a different place, except that recently it seems to have become better and of the reason for it to be improving are blogs like this.

    ( REPLY )
  2. wow – now that’s what i call a good article. keep up the work

    ( REPLY )
  3. My Free Giftcard site
    October 19th, 2011 – 16:12

    I discovered your blog site on google and check just a few of your early posts. Proceed to maintain up the superb operate. I simply extra up your RSS feed to my MSN News Reader. Searching for forward to reading extra from you afterward!…

    ( REPLY )
  4. Surveys for Giftcards
    October 27th, 2011 – 01:18

    You made some first rate factors there. I seemed on the internet for the problem and located most individuals will go along with together with your website.

    ( REPLY )
  5. How To Build A Chicken Coop
    November 1st, 2011 – 06:04

    I think this is one of the most important information for me. And i’m glad reading your article. But should remark on some general things, The website style is wonderful, the articles is really nice : D. Good job, cheers

    ( REPLY )
  6. I have to say that for the past few of hours i have been hooked by the amazing posts on this website. Keep up the great work.

    ( REPLY )

Leave a comment Cancel reply

(required)

(required)



No trackbacks yet.

Green Solution for Simultaneous Cooling and Heating »
« Air Conditioning Duct Designing For Minimum Losses

Recent Posts

  • OPTIMUM CHILLER PLANT SEQUENCE OF OPERATION
  • EFFICIENCY IMPROVEMENT AND OPERATING COST REDUCTION BY BUILDING BMS SYSTEM
  • Salient Features of Energy Efficient Homes
  • Interesting story idea for your readers
  • Coordinated Practices for Green Building Design
  • Use of Thermal Images for Indoor Environmental Control
  • Absorption Chiller Suppliers
  • Improving Efficiency of Existing Data Centers
  • Electric Chiller Suppliers
  • HVAC ENGINEER
  • HVAC ENGINEER
  • ENERGY EFFICIENT OPERATION OF COOLING TOWERS
  • Salient Features of Healthcare AHU
  • Multipurpose Hall Environment Control
  • Piping Network Considerations for Air Conditioning System

Categories

  • Absorption Chiller Suppliers
  • AHU Coils
  • Air Conditioning Systems
  • Air Distribution
  • Air Filtration
  • Air Handling Units
  • Building Management System
  • Chilled Water Plant ΔT
  • Chiller Plant Control Sequence
  • Chillers
  • Combined Cooling Heating & Power Systems
  • Cooling Towers
  • Cost Effective and Energy Efficient Air Side Economizer Systems
  • Data Center Air Conditioning
  • Demand Control Ventilation
  • Displacement Ventilation Systems
  • Ducting System
  • ELECTRIC CHILLER SUPPLIERS
  • Energy Efficient Pumping
  • Energy Recoveries
  • Fans For High Performing HVAC
  • Green Building Design
  • Green Solution
  • Hospital HVAC
  • How to Control Low Chilled Water delta-T
  • HVAC ENGINEERS
  • Indoor Air Quality
  • Insulations
  • Kitchen Ventilation
  • Night Time Precooling
  • Noise Control
  • Optimized Chiller Operation
  • Pumping Solutions
  • Refrigerant Pipng
  • Smoke Management Systems
  • Solar Energy Systems
  • Thermal Energy Storage for Cooling
  • Variable Frequency Drives
  • Variable-Flow Pumping Systems

Archives

 

April 2012
M T W T F S S
« Dec    
  1
2 3 4 5 6 7 8
9 10 11 12 13 14 15
16 17 18 19 20 21 22
23 24 25 26 27 28 29
30  

Recent Comments

  • HVAC Evaporators on Selection of Condensers for Air Conditioning Systems
  • louvre windows on Air Conditioning Systems for Restaurants
  • HAVC Units on How to Achieve Low Humidity Conditions with Minimum Energy Consumption
  • dentist on Identifying Objectionable Noise Sources in Air Conditioning Systems
  • ideas for window treatments for bay windows on High Performance Strategies for Solar Protection

Meta

  • Log in
  • Entries RSS
  • Comments RSS
  • WordPress.org